Release 10.1A: OpenEdge Development:
ADM and SmartObjects
Defining conversion options
In the upper portion of the Conversion Utility window, you specify file directory information, file filter specifications, and conversion options:
![]()
Table B–1 lists and describes the objects you use to set conversion options.
The upper portion of this dialog box also contains a Build File List button. This button is not used to set conversion options and is therefore discussed in the "Building the list of files to process" section instead.
![]()
To set up a converstion option:
- In the Directory fill-in field, specify the directory of the application to be converted.
The directory you choose to specify depends on your conversion strategy. For example, you might decide to convert an entire application, and therefore specify the root directory of the application. Alternatively, your strategy might be to specify only one directory at a time to convert.
Note: Any directory you intend to convert should be either part of thePROPATHor a subdirectory of aPROPATHdirectory.- Using the Include Subdirectories check box, indicate whether to convert files in the subdirectories (or any subdirectories at any lower levels) of the directory identified in
Step 1.- Using the Compile after Conversion check box, indicate whether to compile each file after the conversion attempt.
- In the Filter combo box, specify the types of files to process.
Typically, you convert only .w files. This is because you are converting Version 8 SmartObjects, which normally have the .w extension.
|
Copyright © 2005 Progress Software Corporation www.progress.com Voice: (781) 280-4000 Fax: (781) 280-4095 |